  1. PAC.DOC
  2.  
  3. 2-5-89, 4-5-89.
  4.  
  5. Includes changes from firmware of 12-30-88.
  6.  
  7. Alphabetic list of PK-232 Commands and Parameters by mode, with
  8. short descriptions and defaults.
  9.  
  10. Jeb Boswell, W1YO, 24 Edgewood Park, Springfield, Illinois 62704,
  11. 217) 546-5269.
  12.  
  13. ------------------------------------------------------------------------------
  14.  
  15. Terminal Commands:
  16.  
  17. ACRDISP n    Terminal/screen/printer width, n = characters.
  18.   ACRD n
  19.  
  20. ALFDISP        ON--LF sent to terminal after CR.  Received LF ignored.
  21.   ALFD        OFF--LF not sent.
  22.  
  23. AMTOR        Immediate command to switch to AMTOR ARQ mode standby.
  24.   AM
  25.  
  26. ASCII        Immediate command to switch to ASCII RTTY mode.
  27.   AS
  28.  
  29. AWLEN n        Data bits per word, PK-232 to terminal.
  30.   AW n
  31.  
  32. BAUDOT        Immediate command to switch to Baudot RTTY mode.
  33.   BA
  34.  
  35. BKONDEL        ON--<backspace><space><backspace> echoed for delete.
  36.   BK        OFF--<backslash> echoed for delete.
  37.  
  38. CALIBRATE    Modem calibration routine.
  39.   CAL          K--toggles PTT line.    Q--quits routine.
  40.           H--toggles between wide (1200 hertz) and narrow (200).
  41.           <SPACE>--toggles between mark (low) and space (high) tones.
  42.           D--Alternates between mark and space
  43.              at radio baud (HB) rate.
  44.  
  45. COMMAND n    0 to $7F ASCII character code to enter COMMAND mode from
  46.   COM n          CONVERSE mode.  Default is $03, CTRL-C.
  47.  
  48. CONVERSE    Switch from COMMAND mode to CONVERSE mode, immediate
  49.   CONV or K      command.
  50.  
  51. CUSTOM nnnn    n = 4 digit hex value.  Each bit controls a different function.
  52.   CU nnnn
  53.  
  54. Summary: 
  55. bit 0--0 = display all packets regardless of DCD/Threshold.
  56.        1 = discard all packets too weak to light the DCD LED.
  57.            (1 is default.)
  58. bit 1--0 = MONITOR set to level 4. (Default)
  59.        1 = MONITOR set to level 6.
  60. bit 2--0 = Break does not affect PK-232.
  61.        1 = Break puts PK-232 in Command mode. (Default)
  62. bit 3--0 = Packet channels numbered 0-9.  (Default)
  63.        1 = Packet channels laveled A-J or a-j.
  64. bit 4--0 = Baudot only, no figures before numeral after space.
  65.        1 = Figures before numeral after space--USOS match.
  66.            (1 is default)
  67. bit 5--0 = Power up in command mode. (Default)
  68.        1 = Power up in previous mode.
  69. bit 6--0 = Monitoring disabled in transparent mode. (Default)
  70.        1 = Monitoring active in the transparent mode.
  71.  
  72. Bits 7 to 15 are presently unused.
  73.  
  74. DAYTIME date&time <yymmddhhmm>  See CONSTAMP, DAYSTAMP, MHEARD, and
  75.   DAY          MSTAMP.  See program DAYLOAD.
  76.  
  77. DAYSTAMP    ON--the date is included in CONSTAMP and MSTAMP.
  78.   DAYS        OFF--date is not included.  Default is OFF.
  79.  
  80. DELETE        ON--<DELETE> key to delete while typing.  Default is OFF.
  81.   DEL        OFF--<BACKSPACE> key to delete.  See BKONDEL, REDISPLAY.
  82.  
  83. DISPLAY (class)    (A)sync         asynchronous port parameters.
  84.   DISP        (C)haracter  special characters.
  85.         (F)AX        FAX related parameters.
  86.         (I)d         ID parameters.
  87.         (l)ink         link parameters.
  88.         (M)onitor    monitor paremeters.
  89.         (R)TTY         Baudot/ASCII RTTY, ASMTOR and Morse parameters.
  90.         (T)iming     timing parameters.
  91.         (Z)          display the entire command/parameter list.
  92.  
  93. ECHO        ON--characters from terminal to PK-232 ARE echoed.
  94.   E        OFF--characters are not echoed.  Default is ON.
  95.  
  96. ESCAPE        ON--<ESCAPE>, $1B, is output as '$', $24.
  97.   ES        OFF--<ESCAPE> is output as <ESCAPE>, $1B.
  98.  
  99. FAX        Immediate command to put PK-232 in FAX Mode.
  100.  
  101. FLOW        ON--stops PK-232 output to terminal.  Default is ON.
  102.         OFF--PK-232 output to terminal continues.
  103.  
  104. FULLDUP        ON--full duplex radio operations.
  105.   FU        OFF--full duplex disabled.  Default is OFF.
  106.  
  107. HELP        Help list.
  108.   H
  109.  
  110. HOST        ON--computer friendly mode.  Default is OFF.
  111.   HOST        OFF--normal TNC mode.  <CTRL-A> O H O N <CTRL-W> cancels.
  112.  
  113. MORSE        Immediate commnad to switch to Morse code mode.
  114.   MO          See MSPEED.
  115.  
  116. NEWMODE        ON--automatic Command Mode on disconnect.  Default is ON.
  117.   NE        OFF--no return to Command Mode on disconnect.
  118.  
  119. NOMODE        ON--PK-232 switches modes explicitly--NEWMODE ignored.
  120.   NO        OFF--PK-232 follows NEWMODE.  Default is OFF.
  121.  
  122. NUCR        ON--Null characters are sent to temrinal after <CR>.
  123.   NU        OFF--Null characters not sent.  Default is OFF.
  124.  
  125. NULF        ON--Null characters are sent to terminal after <LF>.
  126.   NUL        OFF--Null characters are not sent.  Default is OFF.
  127.  
  128. NULLS n        Number of nulls to the terminal send when NUCR or
  129.   NULL n      NULF are on.  Default is 0.
  130.  
  131. OPMODE        Shows current mode of operation and status of PK-232.
  132.   O
  133.  
  134. PACKET        Switches the PK-232 to Packet mode, the default mode
  135.   PA          at initial turnon.
  136.  
  137. PARITY n    To terminal.  0 = no parity. 1 = odd parity. 2 = no parity.
  138.   PAR n          3 = even parity.  Transparent mode. See AWLEN.  
  139.  
  140. REDISPLA n    0 - $7F ( 0 - 127 decimal).  Re-display current input line.
  141.   RED n          Default is CTRL-R ($12).
  142.  
  143. RESET        Everything back to "square one".  All personalized
  144.   RESET         parameters and monitor lists are lost.  USE RESTART!
  145.  
  146. RESTART        Same as turning PK-232 off, then on.  Power down reset. 
  147.   RESTART    Not the same as RESET.
  148.  
  149. START n        0 - $7F ( 0 - 127 decimal ) character to start output to
  150.   STA n     terminal after STOP character used.  Default is CTRL-Q.
  151.  
  152. STOP n        0 - $7F ( 0 -127 decimal ) character to stop output to
  153.   STO n        terminal.  START charqcter resumes.  Defualt is CTRL-S.
  154.  
  155. TBAUD n        PK-232 to terminal baud rate.
  156.   TB n
  157.  
  158. TCLEAR        Clears the transmit buffer, cancels further transmission
  159.   TC        of data.  May not clear all packets.
  160.  
  161. TIME N        0 - $7f ( 0 - 127 decimal ) character imbedded to send time.
  162.   TI n        Default is CTRL-T (#14).  DAYSTAMP ON also sends date.
  163.  
  164. TRFLOW        ON--software flow control activated for terminal in
  165.   TRF        Transparent Mode.  OFF--only hardware flow control.
  166.         Software set by STOP and START.  Default is OFF.
  167.  
  168. XFLOW        ON--XON/XOFF terminal software flow control is on.
  169.   XF        OFF--XON/XOFF software flow control off.
  170.         Hardware flow control: START, STOP, XON, XOFF = 0.
  171.         Default is ON.
  172.  
  173. XOFF n        0 - $7F ( 0 - 127 decimal) character to stop input
  174.   XO n        from terminal.  Restart with XON.  Default is CTRL-S.
  175.  
  176. XON n        0 - $7F ( 0 - 127 decimal) character to start input
  177.   XON n        from terminal.  Stop with XOFF.  Default is CTRL-Q.
  178.  
  179. ------------------------------------------------------------------------------
  180.  
  181. AMTOR Commands:
  182.  
  183. AAB        Answer back text to WRU?, maximum of 17 characters.
  184.   AA          WRU set on.  Also ASCII, Baudot.
  185.  
  186. ACHG        Receiving station command for immediate changeover,
  187.   AC          "breadk-in".  Use care.
  188.  
  189. ACRTTY n    1 to 255 characters before automatic CR.
  190.   ACRR n      0 disables.  ( 71 for standard 69 column AMTOR.)
  191.  
  192. ADELAY n    Transmitter keyup delay in 10 msec before data sent.
  193.   AD n
  194.  
  195. ALIST        Immediate switch to ARQ Listen mode--Mode L.
  196.   AL          Repeat AL for synchronization.
  197.  
  198. ARQ aaaa    Starts AMTOR Mode A SELective CALl to a distant station.
  199.   AR aaaa      (See SELCAL.)
  200.  
  201. ARQTMO n    0 to 255 seconds to send an ARQ SELCAL befroe shutdown.
  202.   ARQT n
  203.  
  204. CWID n        Changes the "cwid send" character.  Default is $06, CTRL-F.
  205.   CW          ON sets feature on.  OFF sets feature off.  Obsolete.
  206.  
  207. DCDCONN        ON--RS-232 pin 8 follows the state of the CON LED.
  208.   DC        OFF--pin permanently set high (active).  Default.
  209.  
  210. EAS        ON--display as transmitted.  (Echo As Sent.)
  211.   EAS        OFF--display characters as sent to the PK-232.  Default.
  212.  
  213. FEC        Immediate command for AMTOR FEC (mode B) transmission.
  214.   FE        For CQ and satellite calls.  See SELCAL, ARQ, RCVE, AMTOR.
  215.  
  216. LOCK        Immediate command for measuring Morse code speed and
  217.   L          setting letters in Morse and AMTOR.
  218.  
  219. MYALTCAL aaaa    Alternate SELective CALling identification, for 'all ships
  220.   MYS aaaa      and stations' calls.
  221.  
  222. MYSELCAL aaaa    nnnn = SELective CALling code.
  223.   MYS aaaa
  224.  
  225. NEWMODE        ON--automatic Command Mode on disconnect.
  226.   NE        OFF--no return to Command Mode on disconnect.
  227.  
  228. NOMODE        ON--PK-232 switches modes explicitly--NEWMODE ignored.
  229.   NO        OFF--PK-232 follows NEWMODE.
  230.  
  231. NUMS        Forces FIGURES.
  232.   N
  233.  
  234. RECEIVE n    0 - $7F (1 - 127 decimal). The control character in a file
  235.   R n        to switch from transmit to receive.  Default is CTRL-D ($04).
  236.  
  237. RFEC        ON--Mode B (FEC) signals are displayed in AMTOR standby.
  238.   RF        OFF--not displayed.  Default is ON.
  239.  
  240. RXREV        ON--Received polarity is reversed--mark/space reversal
  241.   RXR        OFF--not reversed.  Default is OFF.
  242.  
  243. SELFEC aaaa    SELective CALling code for specific distant station.
  244.   SEL aaaa    See MUSELCAL.  End SELFEC xmission with CTRL-C and "R"eceive.
  245.  
  246. SRXALL        ON--receive ALL selective transmissions (SELFEC).
  247.   SRX        OFF--Receive only SELCAL-assressed SELFEC transmissions.
  248.           Default is OFF.
  249.  
  250. TCLEAR        Clears the transmit buffer, cancels further transmission
  251.   TC        of data.  May not clear all packets.
  252.  
  253. TXREV        ON--Transmit data polarity is reversed.  Mark-space reversal.
  254.   TXR        OFF--normal.  Default is off.
  255.  
  256. WORDOUT        ON--characters held in transmit buffer until space, or
  257.   WO        punctuation.  OFF--characters sent at once.  Default is OFF.
  258.  
  259. WRU        Always on in AMTOR.
  260.   WR        
  261.  
  262. ------------------------------------------------------------------------------
  263.  
  264. ASCII Commands:
  265.  
  266. AAB <17>    Answer back text to WRU?, maximum of 17 characters.
  267.   AA <17>      WRU set on.  Also AMTOR, Baudot.
  268.  
  269. ABAUD n        ASCII Baud rate from PK-232 to radio.
  270.   AB n          45, 50, 57, 75, 100, 110, 150, 200, 300 bauds available.
  271.  
  272. ACRTTY n    1 to 255 characters before automatic CR.
  273.   ACRR n      0 disables.  ( 71 for standard 69 column AMTOR.)
  274.  
  275. ALFRTTY        ON--LF sent after every CR.  Default.
  276.   ALFR        OFF--LF not sent after every CR.
  277.  
  278. CWID n        Changes the "cwid send" character.  Default is $06, CTRL-F.
  279.   CW          ON sets feature on.  OFF sets feature off.  Obsolete.
  280.  
  281. DIDDLE        ON--sends LTRS in Baudot, NUL (00) ASCII.
  282.   DID        OFF--no character sent.  Default.
  283.  
  284. EAS        ON--display as transmitted.  (Echo As Sent.)
  285.   EAS        OFF--display characters as sent to the PK-232.  Default.
  286.  
  287. NEWMODE        ON--automatic Command Mode on disconnect.
  288.   NE        OFF--no return to Command Mode on disconnect.
  289.  
  290. NOMODE        ON--PK-232 switches modes explicitly--NEWMODE ignored.
  291.   NO        OFF--PK-232 follows NEWMODE.
  292.  
  293. RCVE        Immediate command to switch from Transmit to Receive in
  294.   R        Baudot and ASCII RTTY.  CTRL-C for command mode.
  295.  
  296. RECEIVE n    0 - $7F (1 - 127 decimal). The control character in a file
  297.   R n        to switch from transmit to receive.  Default is CTRL-D ($04).
  298.  
  299. RXREV        ON--Received polarity is reversed--mark/space reversal
  300.   RXR        OFF--not reversed.  Default is OFF.
  301.  
  302. TCLEAR        Clears the transmit buffer, cancels further transmission
  303.   TC        of data.  May not clear all packets.
  304.  
  305. TXREV        ON--Transmit data polarity is reversed.  Mark-space reversal.
  306.   TXR        OFF--normal.  Default is off.
  307.  
  308. WIDESHFT    ON--RTTY tones shift is 1000 hertz.
  309.   WI        OFF--200 hertz.  Default is OFF.
  310.  
  311. WORDOUT        ON--characters held in transmit buffer until space, or
  312.   WO        punctuation.  OFF--characters sent at once.  Default is OFF.
  313.  
  314. WRU        ON--respond to a WRU?
  315.   WR        OFF--no response to WRU?  Default is OFF.
  316.  
  317. XMIT        Immediate command to transmit in Command Mode (CTRL-C for
  318.   X        Command Mode.)
  319.  
  320. ------------------------------------------------------------------------------
  321.  
  322. Baudot Commands:
  323.  
  324. AAB <17>    Answer back text to WRU?, maximum of 17 characters.
  325.   AA <17>      WRU set on.  Also AMTOR, ASCII.
  326.  
  327. ACRTTY n    1 to 255 characters before automatic CR.
  328.   ACRR n      0 disables.  ( 71 for standard 69 column AMTOR.)
  329.  
  330. ALFRTTY        ON--LF sent after every CR.  Default.
  331.   ALFR        OFF--LF not sent after every CR.
  332.  
  333. BITENV n    0 - $1F ( 0 -31 decimal).  Exclusive OR for bit inversion
  334.   BI n        Baudot transmissions.  Default is 0, no bit inversion.
  335.  
  336. CCITT        ON--International Alphabet #2.  Default.
  337.   CC        OFF--American Standard Baudot (Western Union).
  338.  
  339. CODE n        Code 0 with CCITT.  Default.  Code 1: U.S. teleprinter.
  340.   COD n        Code 2: Cyrillic.  Code 3: Transliterated Cyrillic.
  341.         Code 4: Katakana.  Code 5: Transliterated Katakana.
  342.  
  343. CRADD        ON--line end sequence is <CR CR LF>.  (Old standard.)
  344.   CRA        OFF--sequence is <CR LF>.  Default is OFF.
  345.  
  346. CWID n        Changes the "cwid send" character.  Default is $06, CTRL-F.
  347.   CW n        Also, CWID ON sets feature on, CWID OFF sets feature off.
  348.  
  349. DIDDLE        ON--sends LTRS in Baudot, NUL (00) ASCII.
  350.   DID        OFF--no character sent.  Default.
  351.  
  352. EAS        ON--display as transmitted.  (Echo As Sent.)
  353.   EAS        OFF--display characters as sent to the PK-232.  Default.
  354.  
  355. LOCK        Immediate command for measuring Morse code speed and
  356.   L          setting letters in Morse and AMTOR.
  357.  
  358. NEWMODE        ON--automatic Command Mode on disconnect.
  359.   NE        OFF--no return to Command Mode on disconnect.
  360.  
  361. NOMODE        ON--PK-232 switches modes explicitly--NEWMODE ignored.
  362.   NO        OFF--PK-232 follows NEWMODE.
  363.  
  364. NUMS        Forces FIGURES.
  365.   N
  366.  
  367. RBAUD n        On air Baudot baud rate.  Default is 45 bauds.
  368.   RB          45, 50, 57,  75, 100, 110, 150, 200, 300 bauds.
  369.           60, 66, 75, 100, 132, 145, 198, 264, 396 WPM.
  370.  
  371. RCVE        Immediate command to switch from Transmit to Receive in
  372.   R        Baudot and ASCII RTTY.  CTRL-C for command mode.
  373.  
  374. RECEIVE n    0 - $7F (1 - 127 decimal). The control character in a file
  375.   R n        to switch from transmit to receive.  Default is CTRL-D ($04).
  376.  
  377. RXREV        ON--Received polarity is reversed--mark/space reversal
  378.   RXR        OFF--not reversed.  Default is OFF.
  379.  
  380. TCLEAR        Clears the transmit buffer, cancels further transmission
  381.   TC        of data.  May not clear all packets.
  382.  
  383. TXREV        ON--Transmit data polarity is reversed.  Mark-space reversal.
  384.   TXR        OFF--normal.  Default is off.
  385.  
  386. USOS        ON--unshift on space.
  387.   USO        OFF--no unshift on space.  Default is OPP.
  388.  
  389. WIDESHFT    ON--RTTY tones shift is 1000 hertz.
  390.   WI        OFF--200 hertz.  Default is OFF.
  391.  
  392. WORDOUT        ON--characters held in transmit buffer until space, or
  393.   WO        punctuation.  OFF--characters sent at once.  Default is OFF.
  394.  
  395. WRU        ON--respond to a WRU?
  396.   WR        OFF--no response to WRU?  Default is OFF.
  397.  
  398. XMIT        Immediate command to transmit in Command Mode (CTRL-C for
  399.   X        Command Mode.)
  400.  
  401. ------------------------------------------------------------------------------
  402.  
  403. FAX commands:
  404.  
  405. ASPECT n    1 - 6.  Default is 2.  IOC.  Index Of Cooperation.
  406.   ASP n        2: Weather charts.
  407.         3: Wirephoto.
  408.         4: WEFAX Satellite.
  409.  
  410. FAXNEG        ON--reverses picture, negative to positive.
  411.   FAXN        OFF--positive picture.  Default is OFF.
  412.  
  413. FSPEED n    0 - 4.  horizontal scan rate, as follows:
  414.   FS n        1: 1 line/second, 60 lines/minute.
  415.         2: 2 lines/second, 120 lines/minute.
  416.         3: 3 lines/second, 180 lines/minute.
  417.         4: 4 lines/second, 240 lines/minute.
  418.         0; 1.5 lines/second, 90 lines per minute.
  419.         Default is 2.
  420.  
  421. GRAPHICS n    0 - 6.  Horizontal dot density, as follows:
  422.   GR n        0 - 480, 1 - 960 (high quality) (default), 
  423.         2 - 980 (ribbon save), 3 - 1920 (highhest quality),
  424.         4 - 640, 5 - 576, 6 - 720.
  425.  
  426. JUSTIFY n    0 - 15.  Shift image to left 1/2 inch per unit.
  427.   JU n
  428.  
  429. LEFTRITE    ON--left to right print of picture.  Normal.
  430.   LE        OFF--right to left print.  Default is ON.
  431.  
  432. LOCK        Forces synchronization and start of printing.
  433.   L
  434.  
  435. PRCON        ON--Parallel printer connected.
  436.   PRC        OFF--Parallel printer not connected.  Default is OFF.
  437.  
  438. PRFAX        ON--FAX to parallel printer port.  Default is ON.
  439.   PRF        OFF--FAX to RS-232 (terminal) port of PK-232.
  440.         AWLEN 8, 8BITCONV ON, PARity 0, ACRDISP 0.
  441.  
  442. PROUT        ON--All data, text, keyboard sent to parallel printer
  443.   PRO        if PRCON is also on.  OFF--all to RS-232 (terminal).
  444.         Default is OFF.
  445.  
  446. RCVE        Immediate command for receive.  Use instead:
  447.   R        CTRL-D sends FAX stop signal.  CTRL-F sends FAX
  448.         stop signal plus CW ID.
  449.  
  450. XMIT        Immediate command to transmit FAX.
  451.   X
  452.  
  453. ------------------------------------------------------------------------------
  454.  
  455. Morse commands:
  456.  
  457. EAS        ON--display as transmitted.  (Echo As Sent.)
  458.   EAS        OFF--display characters as sent to the PK-232.  Default.
  459.  
  460. LOCK        Immediate command for measuring Morse code speed and
  461.   L          setting letters in Morse and AMTOR.
  462.  
  463. MSPEED        Sets transmit speed, 5 to 99.
  464.   MSP
  465.  
  466. MWEIGHT n    n = 5 to 15.  10 is default, 1:1 dot/space ratio.
  467.   MW n        5 = 0.5:1 ratio.  15 = 1.5:1 ratio.
  468.  
  469. NEWMODE        ON--automatic Command Mode on disconnect.
  470.   NE        OFF--no return to Command Mode on disconnect.
  471.  
  472. NOMODE        ON--PK-232 switches modes explicitly--NEWMODE ignored.
  473.   NO        OFF--PK-232 follows NEWMODE.
  474.  
  475. RECEIVE n    0 - $7F (1 - 127 decimal). The control character in a file
  476.   R n        to switch from transmit to receive.  Default is CTRL-D ($04).
  477.  
  478. TCLEAR        Clears the transmit buffer, cancels further transmission
  479.   TC        of data.  May not clear all packets.
  480.  
  481. WORDOUT        ON--characters held in transmit buffer until space, or
  482.   WO        punctuation.  OFF--characters sent at once.  Default is OFF.
  483.  
  484. XMIT        Immediate command to transmit in Command Mode (CTRL-C for
  485.   X        Command Mode.)
  486.  
  487. ------------------------------------------------------------------------------
  488.  
  489. Packet Commands:
  490.  
  491. 8BITCONV    ON--does NOT strip high order bit in CONVERSE mode.
  492.   8B        OFF--Strips high order bit.  Default is OFF.
  493.  
  494. ACRPACK        ON--CR, the send packet character, is added to all packets.
  495.   ACRP        OFF--not added.  (Converse mode.)  Default is ON.
  496.  
  497. ALFPACK        ON--LF added to each packet after CR.
  498.   ALFP        OFF--no LF added.  Default.
  499.  
  500. AUDELAY n    n = 0 - 120 of 10 msec delay between PTT line clsoed and
  501.   AUD n        start of audio.  Default is 0.
  502.  
  503. AX25L2V2    ON--Version 2 protocol.  Default is ON.
  504.   A        OFF--Version 1 protocol.
  505.  
  506. AXDELAY n    key-up delay for voice repeaters, 10 msec.  0 - 190.
  507.   AXD            Default is 0.
  508.  
  509. AXHANG N    'hang time', 100 msecs.  0 - 20.  Default is 0.
  510.   AXH
  511.  
  512. BEACON EVERY|AFTER n    EVERY--Beacon at regular intervals.
  513.   B            AFTER--After no activity.
  514.             0--off.
  515.             n--10 second intervals, 1 - 250.
  516.  
  517. BTEXT <120>    BEACON text message. Clear with %, &, N, NO, NONE, or OFF.
  518.   BT <120>      (See PASS.)
  519.  
  520. CANLINE n    n = 0 to $7F ASCII code.  CANCEL-LINE input editing
  521.   CAN          command character.  Default is CTRL-X, $18.
  522.  
  523. CANPAC n    n = 0 to $7F ASCII code.  CANCEL-PACKET input editing
  524.   CANP n      command character.  Default is CTRL-Y, $19.
  525.  
  526. CASEDISP n    Characters to display. 0 = as is (no change).  Default.
  527.   CAS n          1 = lower, lower case only.  2 = UPPER, upper case only.
  528.  
  529. CBELL        ON--Three bell characters sent to terminal with "connected
  530.   CB          to" message.  OFF--no bell sent.
  531.  
  532. CFROM all, none, yes, no--accept or reject requests for connect.
  533.   CF        Default is ALL.  Clear with %, &, or OFF.
  534.  
  535. CHCALL        ON--callsign of distant station displayed in multiple
  536.   CHC          connection operation.  OFF--not displayed.  Default is ON.
  537.  
  538. CHDOUBLE    ON--received CHSWITCH characters doubled.  See CHSWITCH.
  539.   CHD              OFF--received CHSWITCH characters not doubled.  Default.
  540.  
  541. CHECK n        1 to 255 is check time in 10 second intervals.  Default = 30.
  542.   CH          0 disables.  Connect timeout.  AX25L2V2 dependent.
  543.  
  544. CHSWITCH n    n is an ASCII character, 0 to $29, $40 to $FF, for new.
  545.   CHS n          connection channel. Default is $00.  
  546.           See CHCALL and CHDOUBLE.
  547.  
  548. CMDTIME n    0 to 255 in 100 msec intervals for timeout in transparent 
  549.   CM n          mode and return to CONVERSE mode.  Default is 1 sec.
  550.  
  551. CMSG        ON--CTEXT message sent on connect request.
  552.   CMS        OFF--CTEXT message not sent.  Default is OFF.
  553.  
  554. CONMODE        CONVERS--automatic CONVERSE mode on connect.  Default.
  555.   CONM        TRANS--automatic TRANSPARENT mode on connect.
  556.  
  557. CONNECT call1 [VIA call2 <,call3,...call9>]  call1 is distant station.
  558.   C call1...      call2 to call9, are digipeaters in path.  See RETRY.
  559.  
  560. CONPERM        ON--Disconnected state not allowed on current connection.
  561.   CONP        OFF--disconnection allowed.  Default.
  562.  
  563. CONSTAMP    ON--connect staus messages are time stamped.
  564.   CONS        OFF--connect status messages are not timestamped.  Default.
  565.  
  566. CPACTIME    ON--Packet transmit timer is used in CONVERSE mode.
  567.   CP        OFF--timer not used.  See PACTIME, SENDPAC, ACRPACK.
  568.           Default is off.
  569.  
  570. CSTATUS        Immediate command to display the status of all channels.
  571.   CS
  572.  
  573. CTEXT <120>    If CMSG is ON, then CTEXT message is sent on connection
  574.   CT <120>      by another station.  120 characters maximum.
  575.  
  576. DCDCONN        ON--RS-232 pin 8 follows the state of the CON LED.
  577.   DC        OFF--pin permanently set high (active).  Default.
  578.  
  579. DFROM all, none, yes/no call1 [, call2, ... call9]  Digipeater request
  580.   DF          control.  Default is ALL.
  581.  
  582. DISCONNE    Immediate command to disconnect from another station.
  583.   D
  584.  
  585. DWAIT n        Delay to Packet transmitter keydown sequence in
  586.   DW n          10 millisecond intervals.  Default is 16 (160 msecs).
  587.  
  588. FRACK n        1 to 15, FRame ACKnowledgement timeout, 1 second intervals.
  589.   FR          Default is 3.
  590.  
  591. HBAUD n        PK-232 to radio baud rate.  45, 50, 57, 75, 100, 110, 150,
  592.   HB n          200, 300, 600, 1200, 2400, 4800, 9600.  Default is 1200.
  593.  
  594. HEADERLN    ON--header and monitored packet on same line.  Default is ON.
  595.   HEAD        OFF--header and packet text on the same line.
  596.  
  597. HID        ON--PK-232 sends HDLC identification as a digipeater.
  598.   HI        OFF--does not send HDLC identification.  Default is OFF.
  599.  
  600. ID        Sends special identification packet on closing a digipeater
  601.   I          station down.  HID must be ON.
  602.  
  603. ILFPACK        ON--PK-232 ignores all LF's from terminal.
  604.   IL        OFF--transmits LF's from terminal.  Default is OFF.
  605.  
  606. KISS        ON--KISS TNC.
  607.   KI        OFF--AX.25 Level 2 TNC.  Default is OFF.
  608.  
  609. MAXFRAME n    1 to 7 limit on unacknowledged packets on a link at
  610.   MAX          one time.  Default is 4.  1 is best for HF.
  611.  
  612. MBX call1[,call2][-'n']  Monitor station.  Call1 and call2 must be 
  613.   MB          in contact for MBX to work.
  614.  
  615. MCON n        Monitor Packet at various levels when connected.  
  616.   MC n          Default is 0.
  617.  
  618. MDIGI        ON--I and UI frames displayed if MYCALL or MYALIAS is
  619.   MD          next digipeater.  OFF--Normal monitoring.  Default is OFF.
  620.  
  621. MFILTER n1[,n2, ... ,n4]  Characters to be excluded from monitored packets,
  622.   MFI ,,,      e.g., CTRL-L, CTRL-Z, etc.  Default is $07, $13.
  623.  
  624. MFROM ALL/NONE or YES/NO call1 ... ,call8.  Display ALL/NONE packets, or 
  625.   MF          YES/NO with call list.  See MTO.  Default is ALL.
  626.  
  627. MHEARD        Immediate command to list stations heard, to a maximum
  628.   MH          of 18.  Disabled by PASSALL ON.  Clear with %, & N, No...
  629.  
  630. MID n        n = 0 - 250 is Morse ID timing in 10 second intervals.
  631.   MI n        0 disables function.
  632.  
  633. MONITOR n    Monitor level setter, 0 to 6. Page 6-73.  Default is 4.
  634.   M n
  635.  
  636. MRPT        ON--Digipeaters in header.  Default is ON.
  637.   MR        OFF--Packets from originating and sestination stations only.
  638.  
  639. MSTAMP        ON--monitored frames are time stamped. See DAYSTAMP, HEADERLN.
  640.   MS          DAYTIME.  OFF--frames are not time stamped.  Default is OFF.
  641.  
  642. MTO ALL/NONE or YES/NO call1[,call2 ...,call8]  Stop display of packets
  643.   MT          addressed to all stations = ALL.  See MFROM.  Default: NONE.
  644.  
  645. MYALIAS call[-n]  Alternate idenity of the PK-232.
  646.   MYA ..
  647.  
  648. MYCALL call[-n]  call = station call sign.  -n = substation ID (SSID).
  649.   MY        Must be used for PK-232 to work packet.  Defautl is PK-232.
  650.  
  651. NEWMODE        ON--automatic Command Mode on disconnect.
  652.   NE        OFF--no return to Command Mode on disconnect.
  653.  
  654. NOMODE        ON--PK-232 switches modes explicitly--NEWMODE ignored.
  655.   NO        OFF--PK-232 follows NEWMODE.
  656.  
  657. PACLEN n    0 to 255 (zero = 255) for length of the data portion 
  658.   PACL    n      of a packet.  Default is 128.
  659.  
  660. PACTIME    EVERY|AFTER n    0 - 250 100 millisecond intervals.
  661.   PACT EVERY|AFTER n    Packetizes input from keyboard EVERY n 100 msec
  662.         interval or AFTER n 100 msecs of no keyboard input.
  663.         Default is 10 (1000 msecs).  Always used in transparent mode,
  664.         and with CPACTIME ON in Converse Mode.
  665.  
  666. PASS n        0 - $07F (0 - 127 decimal)  The character used to "pass" the
  667.   PAS n          next character in Converse mode.  See BTEXT and CTEXT.
  668.           Devault is $16, CTRL-V.
  669.  
  670. PASSALL        ON--PK-232 aceepts packets with bad CRC"s.
  671.   PASSA        OFF--PK-232 accepts packets with valid CRC's only.  Default.
  672.  
  673. PERSIST n    1 - 254 threshold value for a random number attempt to
  674.   PE n        transmit.  0 is 1/256th chance every SLOTTIME, 255 is
  675.         transmit right away.  Default is 127.
  676.  
  677. PPERSIST    ON--The pk-232 uses PERSIST and SLOTTIME parameters in
  678.   PP        executing p-persistant CSMA (Carrier Sense Multiple Accesss).
  679.         OFF--PK-232 uses DWAIT for TAPR-type 1-persistent CSMA.
  680.         Default is OFF.
  681.  
  682. RELINK        ON--automastically tries to relink after time-out on retries.
  683.   REL        OFF--No relink after failed attempt.  Default is OFF.
  684.  
  685. RESPTIME N    0 - 250 delay of 100 milliseconds before sending
  686.   RES n        acknowledgemenat packets.  Default 10.  Prevents collisions.
  687.  
  688. RETRY n        0 - 15 = Number of frame transmission retries before
  689.   RE n        disconnect.  Default is 10.
  690.  
  691. SENDPAC n    0 -$7F ( 0 -127 decimal), the caharacter used to force
  692.   SE n        a packet to be sent in converse mode.  Default is CTRL-M ($0D)
  693.         (<CR>).  See CPACTIME, CR ON.
  694.  
  695. SLOTTIME n    0 - 250 10 millisecond intervals between random number
  696.   SL n        transmit attempts.  Default is 1.
  697.  
  698. SQUELCH        ON--positive squelch.  Stops doubling with voice on Packet
  699.   SQ        channel.  OFF--megative sqyelch.
  700.  
  701. TCLEAR        Clears the transmit buffer, cancels further transmission
  702.   TC        of data.  May not clear all packets.
  703.  
  704. TRACE        ON--trace function on--headers displayed.
  705.   TRAC        OFF--trace off.  Default is OFF.
  706.  
  707. TRANS        Immediate command to switch to Transparent Mode.
  708.   T        Transparent mode for binary file transfer.
  709.  
  710. TRIES n        0 - 15 number of retries on given input channel.
  711.   TRI n        See RETRY.  Also PACLEN and MAXFRAME.  Default is 0.
  712.  
  713. TXDELAY n    0 - 120 10 milliseconds interval after keying PTT line.
  714.   TXD n        Default is 30 (300 milliseconds).
  715.  
  716. TXFLOW        ON--terminal software flow control activated in Transparent
  717.   TXF        mode.  OFF--no software terminal control.  Default is OFF.
  718.  
  719. UNPROTO    call1[ VIA call2[, call3,,, call9]]  Call1 goes to "TO" field.
  720.   U ...        If no call then "CQ".
  721.  
  722. USERS n        0 - 10 simultaneous incoming connections.
  723.   US n        Default is 1.
  724.  
  725. VHF        ON--Packet tones are shifted 1000 hz for VHF.
  726.   V        OFF--200 hz shift.  HBAUD at 300. Default is ON.
  727.  
  728. WHYNOT        ON--reason why packet not displayed.
  729.   WHY        OFF--no reason displayed.
  730.  
  731. XMITOK        ON--PTT line active.
  732.   XMITO        OFF-transmit (PTT) disabled.  Default is ON.
  733.  
  734. ------------------------------------------------------------------------------
  735.  
  736. SIAM (Signal Identification and Acquistion Mode) commands.
  737.  
  738. OK        Sets RXREV, RBAUD or ABAUD, and OPMODE to SIGNAL
  739.   OK        analysis values.
  740.  
  741. SIGNAL        Starts analysis.
  742.   SI
  743.  